Capabilities

Overview
• 32 Bit Windowsฎ Application
• Point and click, web browser-like operation
• Each report page is displayed on screen
• Color-coded arrhythmias
• Color-coded pacer spikes
• No limit to number of patient files that can be
  stored on disk
• PDF Report output
• On-screen help, tutorial, and hints

Analysis Algorithm

• Forest Medical eidos™ Holter Algorithm
• Adjustment for Atrial Fibrillation / Irregular
  Rhythm sensitivity
• Very High Heart Rate analysis capability
  (Sustained rates up to 320 BPM)

Editing
• Enter Cover Page data
• Reconfigure Cover Page
• Delete or add Report Strips
• Delete or add individual episodes, or delete
  all episodes
• Change individual existing beat label
• Insert a beat
• Artifact Category Designation
• Designate Artifact from Full Disclosure
• Manually Designate Paced Beats
• Report data is automatically recalculated
• Parameter Settings
• Change Report Strip Label
• Change Form Label

Advanced Paced Beat Analysis / Reporting
• Total Number of Pacer Spikes Detected
• Total Number of Paced Beats Detected
• Percentage of Pacemaker Dependency
  (Paced Beats/Total Beats)
• Minimum, maximum and average Pacer Rates
• Failure to Capture
• Failure to Sense
• Over-sensing
• Paced Beat Graphs: Rate, Frequency, and R-R
  Histogram

Heart Rate Variability Analysis and Reporting
• Frequency Domain
   – Short Term: 256 beat, 512 beat, 5 minute
      and 256 second interpolated presentations
   – Long Term: 65536 Beat Tachogram, 131072
      Beat Tachogram, and 24-hour Tachogram
      presentations
   – Windowing: Hamming, Hanning, Triangular
      Black, and Harris (or none)
   – Customizable Power Output Table
• Time Domain
   – SDNN, SDANN, SDNN Index, RMSSD,
      and Triangular Index calculations
• 1 Hour Scatter Plots
• R-R Histograms
• ASCII data output capability

Superimposition
• One or two beats
• Variable rate scanning
• One beat or one minute jog-back/jog-forward
• Automatic jog-back based on user reaction time
• R-R histogram or tachogram side display

Q-T Interval Measurement
• Q-T Interval vs. Heart Rate Graph
• Superimposition
• Editing
• Q-T Calculations: Raw, Corrected
• Auto Q-T Calipers

R-R Interval Measurement
• Shortest and Longest R-R Interval
• Time-domain Heart Rate Variability statistics

On-Screen Calipers
• Measure time intervals or ST level
• Caliper Interval Repeat
• Calipers can be saved with strip
• Show Rate Measurements
• Show R-R Interval Measurements

Report
• Memory Card Data (MCD) File Storage
• Memory Card Report (MCR) File Storage
• Copy / paste text into Windows clipboard
• Copy / paste graphs into Windows clipboard
• Customize Report Layout
• One Page Report Option

Cover Page
• Patient Information
• Medications / Symptoms
• Print Logo
• Physician Information
• Referring Physician Information
• Conclusions
• Parameter Settings
• ICD-9 CM Drop Down Box

Narrative Summary
• Total QRS Complexes
• Average, Maximum, and Minimum Heart Rate
• Total Ventricular Ectopic Beats (VE)
• Isolated Ventricular Ectopic Beats
• Bigeminy, duration
• Trigeminy episodes
• Couplets (VE Pairs)
• Ventricular Runs, duration, longest and fastest
• Idio-ventricular Rhythm (<100 BPM)
• Total Supraventricular Ectopic Beats (SVE)
• Isolated Supraventricular Ectopic Beats
• SVE Pairs
• SV Bigeminy
• SV Trigeminy
• Supraventricular Tachycardia (SVT),
  duration, longest and fastest
• Irregular Rhythm, duration
• Tachycardia, duration
• Bradycardia, duration
• Pauses (Asystole)
• Longest Pause (Asystole)
• ST Depression / Elevation
• Patient Events
• Pacemaker Analysis (Total Paced  Beats, Failure
  to Capture, Failure to Sense)
 
Hourly Summary
• Customizable
• Average, Maximum, and Minimum Heart Rate
• Isolated Ventricular Ectopic Beats
• Bigeminy
• Trigeminy
• Couplets (VE pairs)
• Ventricular Runs
• Isolated Supraventricular Ectopic Beats
• SV Couplets
• SVE Pairs
• SV Bigeminy
• SV Trigeminy
• Supraventricular Tachycardia (SVT)
• Tachycardia
• Irregular Rhythm
• Bradycardia
• Pauses (Asystole)
• ST Depression / Elevation
• Patient Events

Graphs
• Heart Rate
• Ventricular Ectopics
• Ventricular Runs
• Supraventricular Ectopics
• Supraventricular Tachycardia
• Artifact Index (2 or 3 channel)
• ST Level (2 or 3 channel)
• Normal R-R Histogram
• Abnormal R-R Histogram
• Pacer Rate
• Pacer R-R Histogram
• Q-T Graph
• Pause Graph

R-R Scatter Plot  (per hour)


Ventricular Forms
• Beat Count and Sample of up to 32
  Ventricular Forms
• Beat Count and Sample of up to 32 Normal Forms
• Reclassify Forms by Prematurity and Shape
• Turn off a channel

Strips
• Automatic Report Strips in full-scale (25 mm/sec)
  or mini-scale (8.5 mm/sec) format
• Automatic Report Strips 8, 18, or 32 per page
• Strip List
• Extract strip from any time in the
  monitoring period
• Extract all strips for an episode type

Full Disclosure
• Print in 1 Hour Increments
• 15, 30, or 60 seconds per line
• 1 Channel Only
• Any combination of 2 or 3 channels
• Patient event indicated by circle
• Episode Count at end of line (HR, VEs, ST, SVEs)

Alternate Outputs
• Graphs bitmapped to clipboard
• Text bitmapped to clipboard
• Summary Report ASCII text upload
• MCR File – “report-only” file (typ. <100 KB)
• MIT format
• PDF Output
• Fax reports

Pediatrics
• Rate Parameter Settings
• High Rate Algorithm
• Under 20 kg Patients

Electronic Medical Records Support

Supported Recorders
• Trillium 2000™ Holter Recorder
• Trillium 4000™ Holter Recorder
• Trillium 5000™ Holter Recorder
• Trillium 3000™ Holter Recorder/Analyzer

Minimum Computer Requirements

Windows 98SE; 2000; or XP, 150 MHz PII or above, 32 MB of Memory, 100 MB of Hard Disk space, SVGA Video, (2) available USB Ports, and a 300 dpi or higher resolution printer

Available Downloads

Trillium Platinum Holter Analysis
  Software
 Data Sheet (189 KB)

Trillium 2000 Holter Recorder
   Data Sheet (90 KB)
Trillium 4000™ Holter Recorder
   Data Sheet (PDF: 93 KB)
Trillium 5000™ Holter Recorder
   Data Sheet (PDF: 98 KB)
Trillium 3000 Holter Recorder/Analyzer
   Data Sheet (104 KB)
Summary Report
   (PDF: 612 KB)
Full Scale Strips
   (PDF: 687 KB)
Strips 8 Per Page
   (PDF: 919 KB)
Strips 18 Per Page
   (PDF: 194KB)
Strips 32 Per Page
   (PDF: 829 KB)
Full Disclosure 15 Seconds
   (PDF: 1,156 KB)
Full Disclosure 30 Seconds
   (PDF: 523 KB)
Full Disclosure 60 Seconds
   (PDF: 277 KB)
HRVf Long Term Analysis
   (PDF: 1,278 KB)
HRVf Short Term Analysis
   (PDF: 51 KB)
Time Domain Analysis
   (PDF: 8 KB)


Sample Screens
To view sample screens, please select the Screens button at left or this link which will take you to the first screen.
   
 

Phone: 800-844-2037 • 315-434-9000 • Fax: 315-432-8064

 

Home | Site Map | Feedback | Information | Search
Trillium Platinum | Screens

 

Please e-mail webmaster@forestmedical.com with questions or comments about this web site.
Copyright ฉ 2007 by Forest Medical, LLC.  All rights reserved.